请使用支持JavaScript的浏览器!
主营:分子类,蛋白类,抗体类,生化类试剂
℡ 4000-520-616
℡ 4000-520-616
SMOBIO/[QP3110] Q-PAGE™ Bis-Tris Precast Gel (Midi, 12 wells, 8%), 10 gels/Midi, 12 wells, 8%), 10 gels
市  场 价:¥0.00
场      地:美国(厂家直采)
联系QQ:1570468124
电话号码:4000-520-616
邮      箱: info@ebiomall.com
美  元  价:待定
品      牌: SMOBIO
公      司:SMOBIO
公司分类:
SMOBIO/[QP3110] Q-PAGE™ Bis-Tris Precast Gel (Midi, 12 wells, 8%), 10 gels/Midi, 12 wells, 8%), 10 gels
商品介绍

Description 

Q-PAGE™ Bis-Tris Precast Gel is a high-performance and easy to use precast polyacrylamide gel for electrophoresis in Bis-Tris buffer system (MOPS or MES). The optimized gel formula allows Q-PAGE™ Bis-Tris Precast Gel to show improved resolution, accurate results, and an extended shelf-life over conventional Tris-Glycine gels. 

Q-PAGE™ Bis-Tris Precast Gels are available in gradient (4 to 12%) and fixed (8% and 12%) concentrations of polyacrylamide in 12-and 15-well formats. Two available cassette sizes, Mini (10 x 8.3 cm) and Midi (10 x 10 cm), are compatible with most popular protein electrophoresis systems. Q-PAGE™ Mini (QP2XXX) Gels are suitable for Bio-Rad® and other systems. Q-PAGE™ Midi (QP3XXX) Gels are suitable for Invitrogen® XCell SureLock® Mini-Cell, Invitrogen® Mini Gel Tank, Hoefer SE260, and other systems.

Key Features

  • User-friendly gel cassette:

    • Numbered and framed wells for sample loading

    • With cassette opener for easy use

  • Enhanced gel performance:

    • Enhanced band sharpness

    • Better resolution of small proteins

    • Stable for shipping at ambient temperature

  • Easy compatibility: 

    • Available as homogeneous and adjusted gradient gels for a wide range of protein separation.

    • Compatible with most popular protein electrophoresis systems 

Storage and stability

Store Q-PAGE™ Precast Gels at 4°C for periods up to 12 months.

Do not freeze Q-PAGE™ Precast Gels Remove tape and comb before electrophoresis. 

Technical

Clear and sharp bands, high resolution

Q-PAGE™ Bis-Tris Precast Gel shows high resolution of protein separation.

 QP3110 Specifications

Gel

Bis-Tris

Buffer systems

MOPS and MES

Features

Clear and sharp bands,

high resolution

Cassette size

Midi Gel

(10 X 10 cm)

Gel dimensions

8.1 x 8.1 x 0.1 cm

(W x L x thickness) cm

Electrophoresis system

Mini Gel Tank

XCell SureLock,

Hoefer SE260

Well format &

Capacity

12 wells,

40 μl/well

Gel percentage

8 %

Accessory tray

Production description

Tip card

Gel remover

Cassette opener

  

Manual

Manual_Q-PAGE™ Bis-Tris Precast Gel, Midi

SDS

SDS_Q-PAGE™ Precast Gel

Migration pattern

 
 

Setting Up and Running Q-PAGE™ Midi Precast Gel

 

 
 

Removing Q-PAGE from cassette

 
 

Setting up gel/membrane sandwich for Western transfer

 

 

Recommendations/Tips for Gel Running

1. Remove comb and tape before adaption. 2. Use fresh 1X running buffer for the inner cathode chamber.       3. Do not use Tris-Glycine running buffer for Q-PAGE™ Bis-Tris Precast Gels.    4. Rinse the wells before sample loading.

 

Sample Preparation for SDS-PAGE

1. Mix protein sample with 2X sample buffer. 
 

2. Heat the diluted samples at 95°C for 5 min or at 70°C for 10 min.

3. Cool the diluted samples to 4°C and spin down the water condensed on tube surface. (If there is high viscosity part at bottom of tube, transfer supernatant to a new tube.) 

Prepare Q-PAGE™ for Sample Loading

1.Open the blister tray of Q-PAGE™ Precast Gel.

2.Briefly rinse the gel cassette with ddH2O.

3.Remove tape and comb; avoid squeezing the gel.

4.Adapt Q-PAGE™ to electrophoresis system; instruction is provided below. (Invitrogen® Mini Gel Tank is recommended.) 

5.Use a pipette to gently wash the wells with running buffer to remove residual storage buffer. 

6.Fill the wells with running buffer prior to sample loading. 

7.Load samples and pre-stained protein marker into numbered wells.

8.Fill both inner and outer chambers with running buffer to the highest level. Ensure gel wells are completely covered. 

 Power Setting for Running Q-PAGE™

Optimize the voltage and running time if needed.

 

130 V

180 V

230 V*2

Running Time*1

60-75 mins

35-50 mins

25-40 mins

Expected Current

Initial (per gel)

Final (per gel)

 

70-80 mA

20-30 mA

 

90-100 mA

35-45 mA

 

130-140 mA

60-70 mA

Expected temperature

25-30°C

25-35 °C

35-45°C

*1 Set voltage higher than 100 V is recommended.

*2 For higher voltage conditions, please use fresh running buffer for inner and outer chambers.

*3 Running time varies depending on gel percentage, running buffer, temperature, and power supply.  

Remove Q-PAGE™ Midi Gel from Cassette

Open cassette immediately after electrophoresis. Avoid gel drying.

1.Insert the cassette opener into corners of cassette. 

2.Sequentially pry the opener to separate the two plates. 

3.Gently pull up notched plate and let gel stay on the front plate.

4.Use cassette opener to push through the slot in the cassette.

5.Carefully detach the gel from the bottom of gel  

        - Avoid diagonally peeling the gel from the corner.

- If necessary, cut well separators with gel remover

6.Gently remove the gel for further staining or Western blotting. 

Gel Staining 

Proteins separated using Q-PAGE™ Precast Gels can be further stained with most popular staining reagents, such as Coomassie dyes (R-250 or G-250), Silver-stain solution,

and FluoroStain™ Protein Fluorescent Staining Dye. (Cat. No. PS1000)  

Transferring Protein from Q-PAGE™ to Blotting Membrane

1. After protein separation using Q-PAGE™, gently detach QPAGE™ from cassette and then equilibrate the gel in transfer buffer.

2. Pre-soak blotting membrane and filter papers in transfer buffer.

    *Activate PVDF membrane in methanol before soaking in transfer buffer.

    **Prepare 6 filter papers for one gel/membrane sandwich. 

3. Assemble transfer sandwich by orientating cathode, sponge, filter papers, gel, membrane, filter papers, sponge, and anode. The protein goes to the direction of cathode to anode.

4. Carefully move roller over the gel/membrane to remove air bubbles and excess buffer until complete contact is established.

5. Insert transfer cassette into transfer module. Notice that black side of cassette should be next to black side of module.

6. Fill transfer tank with pre-cooled transfer buffer to the highest water level.

7. Set constant voltage at 100 V. Transfer for 90 minutes at low temperature condition. Pre-stained protein marker should be visible on the membrane after transfer is completed.

    Transfer of proteins to the membrane can be checked using Ponceau S staining before blocking step. 

Supplemental Information for Using Q-PAGE™ Precast Gel  

Adapting Q-PAGE™ Midi Precast Gels to Invitrogen Mini Gel Tank Electrophoresis System 

1. Place the Q-PAGE Midi Precast Gels with notched plate facing toward yourself. No extra adapter is needed.

2. Seat the gels on the bottom of Mini Gel Tank and close the cassette clamp.

3. Fill chambers with running buffer to the level of the fill line. Ensure gel wells are completely covered. 

Adapting Q-PAGE™ Midi Precast Gels to other electrophoresis system, please follow the manufacturer’s instruction. 

Buffer recipes 

2X sample buffer with reducing agent  

62.5 mM Tris-HCl pH 6.8, 2% SDS, 25% (v/v) glycerol, 0.01% bromophenol blue, 5% β-mercaptoethanol or 100 mM DTT (added fresh)

 

10X MOPS running buffer 

60.6 g Tris base, 104.6 g MOPS, 10.0 g SDS, 3.0 g EDTA.  Bring up the volume to 1 L with ddH2O. 

10X MES running buffer 

60.6 g Tris base, 97.6 g MES, 10.0 g SDS, 3.0 g EDTA.  Bring up the volume to 1 L with ddH2O. 

1X running buffer 

Dilute 100 ml 10X running buffer with 900 ml ddH2O. 

10X transfer buffer 

30.0 g Tris base, 144.0 g Glycine. Bring up the volume to 1 L with ddH2O. 

1X transfer buffer 

*Cool 1X transfer buffer to 4°C before using.

Dilute 100 ml 10X transfer buffer with 200 ml methanol and 700 ml ddH2O.

**Add SDS to 0.1% to promote transfer of high molecular weight proteins.  

 

 

Troubleshooting Guidelines

Problem

Possible Cause

Suggested Solution

Well deformation

Pull one side of comb out of cassette.

Smoothly pull the comb straight out of the cassette.

Bubbles between gel and cassette

Gel has been frozen or stored at wrong temperature.

Store Q-PAGE Precast Gels at 4°C.

Buffer leaking from the inner chamber

Untight assembly of gels to the electrode modules

Reassemble Q-PAGE gels into the electrodemodules.

Fill outer chamber with 1X running buffer to thehighest level.

Samples do not sink into the wells.

Residual gel storage buffer in the wells

Rinse the gel wells with ddH2O or 1X running bufferbefore loading.

Insufficient sample buffer

Use more sample buffer to prepare samples.

Current is zero and sample do not migrate into gel

Tape at bottom of gel not removed

Remove tape

Gels run faster or more slowly than expected.

Incorrect running buffer

Check buffer composition.

Use fresh 1X running buffer for inner chamber.

Crooked bands at middle or bottom of gel

Gel has been frozen or stored at wrong temperature.

Store Q-PAGE Precast Gels at 4°C.

Incorrect running buffer

Check buffer composition.

Use fresh 1X running buffer for inner chamber.

Band pattern curves toward one or both sides of gel.

Buffer leaking from the inner chamber

Check assembly of gels into the electrode modules.

Excessive heating of gel

Check buffer composition. Or dilute running bufferto 0.5-0.75X.

Do not exceed recommended running conditions.

Insufficient buffer in inner or outer buffer chamber

Fill inner and outer chambers to completely covergel wells.

Poor resolution or fuzzy bands

Excessive heating of gel

Check buffer composition.

Do not exceed recommended running conditions.

Incorrect running buffer

Check buffer composition.

Bands are missing on the membrane after Westerntransferring.

Proteins move in the wrong direction

Check the order of gel/membrane sandwich assembly,the direction of transfer cassette in transfer modules, and the polarity ofconnections to power supply.

Swirls or missing bands; bands trail off in multipledirections on the membrane after Western transferring.

Contact between the membrane and the gel was poor;Air bubbles or excess buffer remains between the blotting membrane andthe gel. 

Use thicker/more filter paper in the gel/membranesandwich

Remove air bubbles and excess buffer betweengel and membrane by carefully moving the roller over the membrane.

Apparent molecular sizes of prestained proteinmarkers are different as indicated.

Prestained protein markers used have not beencalibrated for use with Q-PAGE gels. Dyes for staining protein markers affect themigration patterns of prestained proteins in different buffer systems.

Calibrate prestained protein markers againstunstained proteins of known size or use SMOBIO’s ExcelBand™ Protein Markers.

Q-PAGE™ Precast Gel 

Gel Type

Bis-Tris

TGN (Tris-Glycine-Novel)

Buffer systems

MOPS and MES

Tris-Glycine (Laemmli)

Features

Clear and sharp bands, high resolution

Quick running, clear bands

Cassette size

Mini Gel(10 x 8.3 cm)

Midi Gel(10 X 10 cm)

Mini Gel(10 x 8.3 cm)

Midi Gel(10 X 10 cm)

Electrophoresis system

Bio-Rad systems

Mini Gel Tank

Xcell SureLock,

Hoefer SE260

Bio-Rad systems

Mini Gel Tank

Xcell SureLock,

Hoefer SE260

Well format &

Capacity

12 wells, 25 μl/well

15 wells, 22 μl/well

   12 wells,    40 μl/well

15 wells,  28 μl/well

 12 wells,    25 μl/well

   15 wells,       22 μl/well

12 wells,   40 μl/well

15 wells,   28 μl/well

Gel percentage/

Cat. No.

8%

8%

8%

8%

10%

10%

10%

10%

QP2110

QP2120

QP3110

QP3120

QP4210

QP4220

QP5210

QP5220

12%

12%

12%

12%

4-15%

4-15%

4-15%

4-15%

QP2310

QP2320

QP3310

QP3320

QP4510

QP4520

QP5510

QP5520

4-12%

4-12%

4-12%

4-12%

 

 

 

 

QP2510

QP2520

QP3510

QP3520

 

 

 

 

Odoo - Sample 1 for three columns

ExcelBand™ Protein Markers

  • Ready-to-use— premixed with a loading buffer for direct loading, no need to boil

  • Broad range310 kDa to 5 kDa

  • Pre-stained bands for monitoring protein separation during electrophoresis and Western blotting transferring efficiency on membrane

  • Enhanced bands— for quick reference

Odoo - Sample 3 for three columns

YesBlot™ Western Marker I

  • Ready-to-use — no need of mixing or heating before sample loading

  • Direct visualization — 10 IgG-binding proteins for direct visualization on Western blots

  • Pre-stained bands — 4 pre-stained proteins for monitoring protein separation during electrophoresis and Western blotting transferring efficiency on membrane

  • Wide range — 10 clear bands from 15 to 200 kDa for size estimation

  • Quick reference — two enhanced bands (30 and 80 kDa)

Odoo - Sample 3 for three columns

FluoroStain™ Protein Fluorescent Staining Dye

  • Compatible to MASS analysis — compatible to the analysis of mass spectra, such as LC-MS/MS, MALDI-TOF, and etc.

  • High sensitivity — detection level achieve ~3 ng, similar to silver staining

  • Substitution of the Coomassie Blue protein staining method

品牌介绍

SMOBIO


SMOBIO成立于2004年,公司在开发和制造分子生物学试剂和测试工具方面表现优异。其分子生物学试剂是市场上最受欢迎的一部分。提供的蛋白质标记物包含具有广谱预染蛋白的即用型稳定混合物,范围从50bp到25kb。此外,SMOBIO提供各种DNA聚合酶和逆转录酶,可以针对不同的实验室应用进行优化。专注领域:蛋白质标记、DNA梯度、PCR相关产品、克隆载体、荧光加载和染色染料、RT-PCR相关产品、Taq DNA聚合酶、Western Marker、dNTP等。


2004年,SMOBIO Technology,Inc.迅速出现在生物技术行业。SMOBIO Technology,Inc.首先采用独特的发酵技术,旨在生产高质量的功能性食品成分。建立成功的分销网络后,我们将继续专注于高质量产品,并开发了最先进的生物分子测试工具。我们的工具旨在通过提供高质量的DNA阶梯和蛋白质标记物来促进分子生物学和蛋白质科学研究。这些创新产品已受到业界和学术界人士的高度评价。自2008年以来,SMOBIO Technology,Inc.已展示出非常可观的市场份额。客户满意的证据表明,SMOBIO Technology,Inc.竭尽全力生产高质量的产品。


产品列表:


斯莫比

 TP1000

 ExcelTaq DNA聚合酶,5 U /μl,500 U x 1

500 U x 1

斯莫比

 TK1000

 ExcelTaq Klen-Taq DNA聚合酶,5 U /μl,500 U x 1

500 U x 1

斯莫比

 TF1000

 ExcelTaq SMO-HiFi DNA聚合酶,5 U /μl,500 U x 1

500 U x 1

斯莫比

 TP1100

 ExcelTaq 5X PCR预混液,200 Rxn

200 Rxn

斯莫比

 TP1200

 ExcelTaq 5X PCR主染料混合物,200 Rxn

200 Rxn

斯莫比

 TP1260

 ExcelTaq 5X荧光PCR预混液,200 Rxn

200 Rxn

斯莫比

 TP2000

 ExcelTaq血液直接DNA聚合酶,5 U /μl,500 U x 1

500 U x 1

斯莫比

 TP2100

 ExcelTaq 5X Blood Direct PCR Master Mix Kit,200 Rxn

200 Rxn

斯莫比

 TQ1100

 ExcelTaq Q-PCR预混液,200 Rxn

200 Rxn

斯莫比

 CV1000

 GetCloneTMPCR克隆载体,20 Rxn

200 Rxn

斯莫比

 RP1000

 ExcelRT反转录酶,20,000单位,100μl100 Rxn

100微升100 Rxn

斯莫比

 RP1100

 ExcelRT一步式RT-PCR试剂盒,50 Rxn

50 Rxn

Protein 相关产品

斯莫比

 PM1500

 ExcelBand全蓝色常规范围蛋白质标记物,250μlx 2

250微升×2

斯莫比

 PM1600

 ExcelBand全蓝色常规范围加蛋白质标记物,250μlx 2

250微升×2

斯莫比

 PM1700

 ExcelBand全蓝色广谱蛋白质标记物,250μlx 2

250微升×2

斯莫比

 PM2400

 ExcelBand粉色蓝色蛋白质标记物,250μlx 2

250微升×2

斯莫比

 PM2500

 ExcelBand 3色常规蛋白质标记物,250μlx 2

250微升×2

斯莫比

 PM2600

 ExcelBand 3色高范围蛋白质标记物,250μlx 2

250微升×2

斯莫比

 PM2700

 ExcelBand 3色广谱蛋白质标记物,250μlx 2

250微升×2

斯莫比

 PM5000

 ExcelBand 3色预染蛋白梯标准范围,250μlx 2

250微升×2

斯莫比

 PM5100

 ExcelBand 3色预染蛋白梯子高量程,250μlx 2

250微升×2

斯莫比

 PM5200

 ExcelBand 3色预染蛋白梯子,宽范围,250μlx 2

250微升×2

斯莫比

 PS1000

 FluoroStain蛋白荧光染色染料(红色,1000X),1毫升

1毫升

斯莫比

 PS1001

 FluoroStain蛋白荧光染色染料(红色,1000X),1 ml x 5

1毫升x 5

斯莫比

 PS2000

 FluoroStain蛋白荧光染色染料(金,100X),10毫升

10毫升

DNA 相关产品

斯莫比

 DM1100

 ExcelBand 50 bp DNA梯子,500μl

500微升

斯莫比

 DM2100

 ExcelBand 100 bp DNA梯子,500μl

500微升

斯莫比

 DM2300

 ExcelBand 100 bp + 3K DNA梯子,500μl  

500微升

斯莫比

 DM3100

 ExcelBand 1KB(0.25-10 kb)DNA梯子,500μl  

500微升

斯莫比

 DM3200

 ExcelBand 1KB Plus(0.1-10 kb)DNA梯子,500μl  

500微升

斯莫比

 DM4100

 ExcelBand XL 25 kb DNA梯子,宽量程(最高25 kb),500μl

500微升

斯莫比

 DM1160

 FluoroBand 50 bp荧光DNA梯子,500μl

500微升

斯莫比

 DM2160

 FluoroBand 100 bp荧光DNA梯子,500μl

500微升

斯莫比

 DM2360

 FluoroBand 100 bp + 3K荧光DNA梯子,500μl  

500微升

斯莫比

 DM3160

 FluoroBand 1KB(0.25-10 kb)荧光DNA梯子,500μl  

500微升

斯莫比

 DM3260

 FluoroBand 1KB Plus(0.1-10 kb)荧光DNA梯子,500μl  

500微升

斯莫比

 DM4160

 FluoroBand XL 25 kb荧光DNA梯子,宽量程(最大25 kb),500μl

500微升

斯莫比

 DL1000

 ExcelDye 6X DNA加载染料,橙色,5毫升x 2

5毫升x 2

斯莫比

 DL2000

 ExcelDye 6X DNA加载染料,绿色,5毫升x 2

5毫升x 2

斯莫比

 DL3000

 ExcelDye 6X DNA加载染料,蓝色,5毫升x 2

5毫升x 2

斯莫比

 DL4000

 ExcelDye 6X DNA加载染料,三色,5 ml x 2

5毫升x 2

斯莫比

 DL5000

 FluoroDye DNA荧光加载染料(绿色,6X),1毫升  

1毫升 

斯莫比

 DL5001

 FluoroDye DNA荧光加载染料(绿色,6X),1 ml x 5

1毫升x 5

斯莫比

 DS1000

 FluoroStain DNA荧光染色染料(绿色,10,000X),500μl

500微升

斯莫比

 DS1001

 FluoroStain DNA荧光染色染料(绿色,10,000X),500μlx 5

500微升x 5

LED Light Box 切胶仪

斯莫比

 VE0100

 B-BOXTM蓝光LED落射照明器,DC 12伏,0.72安培

1套

斯莫比

 VE0101

 适配器,AC 100-240V,50/60 Hz,1.8 m电源线,1 /包

斯莫比

 VE0102

 用于B-BOXTM的多角度滤板,1 /包

斯莫比

 VE0103

 用于B-BOXTM的琥珀色护目镜,1 /包



自营商城图标
厂家直采
全球直采 正品优价
正品保障图标
正品保障
厂家直发 有线跟踪
解放采购图标
正规清关
CIF100%正规报关,提供发票
及时交付图标
及时交付
限时必达 不达必赔