Description
Q-PAGE™ TGN (Tris-Glycine Novel) Precast Gels are ready-to-use acrylamide gels for SDS-PAGE running in Tris-Glycine buffer system. With unique formula, Q-PAGE™ TGN Precast Gels perform enhanced speed, better separation, and longer shelf life as compared with conventional Laemmli Tris-HCl gels. The protein migration patterns in Q-PAGE™ TGN series, however, are similar with typical Laemmli Tris-HCl gels, and thus Q-PAGE™ TGN Precast Gels are compatible to traditional SDS-PAGE and subsequent analyses.
Q-PAGE™ TGN Precast Gels are available in gradient (4 to 15%) and fixed (10%) concentrations of polyacrylamide in 12- and 15-well formats. Two available cassette sizes, Mini (10 x 8.3 cm) and Midi (10 x 10 cm), are compatible with most popular protein electrophoresis systems. Q-PAGE™ Mini (QP4XXX) Gels are suitable for Bio-Rad® and other systems. Q-PAGE™ Midi (QP5XXX) Gels are suitable for Invitrogen® XCell SureLock® Mini-Cell, Invitrogen® Mini Gel Tank, Hoefer SE260, and other systems.
Key Features
User-friendly gel cassette:
Numbered and framed wells for sample loading
Labeled warning sign and green tape as reminder
Enhanced gel performance:
Enhanced gel electrophoresis speed
Better band separation
Stable for shipping at ambient temperature
Easy compatibility:
Available as homogeneous and adjusted gradient gels for a wide range of protein separation.
Compatible with most popular protein electrophoresis systems
Storage and stability
Store Q-PAGE™ Precast Gels at 4°C for periods up to 12 months.
Do not freeze Q-PAGE™ Precast Gels. Remove tape and comb before electrophoresis.
Technical
Q-PAGE™ TGN Precast Gel can separate protein in 19 minutes using 300 V.
QP5220 Specifications
Gel | TGN(Tris-Glycine-Novel) | |
Buffersystems | Tris-Glycine (Laemmli) | |
Features | Quickrunning, clear bands | |
Cassettesize | Midi Gel (10 X 10 cm) | |
Geldimensions | 8.1 x 8.1 x0.1 cm (W x L xthickness) cm | |
Electrophoresissystem | Mini Gel Tank XCell SureLock, Hoefer SE260 | |
Well format& Capacity | 15 wells, 28 μl/well | |
Gelpercentage | 10 % | |
Accessorytray | Productiondescription Tip card Gel remover Cassetteopener |
Manual
Manual_Q-PAGE™ TGN Precast Gel, Midi
SDS
SDS_Q-PAGE™ Precast Gel
Migration pattern
Recommendations/Tips for Gel Running
1. Remove comb and tape before adaption. 2. Use fresh 1X running buffer for the inner cathode chamber. 3. Rinse the wells before sample loading. 4. Try 200 V first, and optimize the voltage and running time if needed. Do not set voltage lower than 100 V.
Sample Preparation for SDS-PAGE
1. Mix protein sample with 2X sample buffer.
2. Heat the diluted samples at 95°C for 5 min or at 70°C for 10 min.
3. Cool the diluted samples to 4°C and spin down the water condensed on tube surface. (If there is high viscosity part at bottom of tube, transfer supernatant to a new tube.)
Prepare Q-PAGE™ for Sample Loading
1.Open the blister tray of Q-PAGE™ Precast Gel.
2.Briefly rinse the gel cassette with ddH2O.
3.Remove tape and comb; avoid squeezing the gel.
4.Adapt Q-PAGE™ to electrophoresis system; instruction are provided below. (Invitrogen® Mini Gel Tank is recommended.)
5.Use a pipette to gently wash the wells with running buffer to remove residual storage buffer.
6.Fill the wells with running buffer prior to sample loading.
7.Load samples and pre-stained protein marker into numbered wells.
8.Fill both inner and outer chambers with running buffer to the highest level. Ensure gel wells are completely covered.
Power Setting for Running Q-PAGE™
Optimize the voltage and running time if needed.
| 150 V | 200 V*2 | 250 V*3 | 300 V*3 |
Running Time*1 | 50-70 mins | 35-55 mins | 25-40 mins | 15-30 mins |
Expected Current Initial (per gel) Final (per gel) |
35-45 mA 10-20 mA |
45-55 mA 20-25 mA |
75-85 mA 40-45 mA |
100-110 mA 60-70 mA |
Expected temperature | 25-30°C | 25-30 °C | 25-35°C | 30-40°C |
*1 Set voltage higher than 100 V is recommended.
*2 Try 200 V first, and optimize the voltage and running time if needed
*3 For higher voltage conditions, please use fresh running buffer for inner and outer chambers
*4 Running time varies depending on gel percentage, running buffer, temperature, and power supply.
Remove Q-PAGE™ Gel from Cassette
Open cassette immediately after electrophoresis. Avoid gel drying.
1.Insert the cassette opener into corners of cassette.
2.Sequentially pry the opener to separate the two plates.
3.Gently pull up notched plate and let gel stay on the front plate.
4.Use cassette opener to push through the slot in the cassette.
5.Carefully detach the gel from the bottom of gel.
- Avoid diagonally peeling the gel from the corner.
- If necessary, cut well separators with gel remover.
6.Gently remove the gel for further staining or Western blotting.
Gel Staining
Proteins separated using Q-PAGE™ Precast Gels can be further stained with most popular staining reagents, such as Coomassie dyes (R-250 or G-250), Silver-stain solution,
and FluoroStain™ Protein Fluorescent Staining Dye. (Cat. No. PS1000)
Transferring Protein from Q-PAGE™ to Blotting Membrane
1. After protein separation using Q-PAGE™, gently detach QPAGE™ from cassette and then equilibrate the gel in transfer buffer.
2. Pre-soak blotting membrane and filter papers in transfer buffer.
*Activate PVDF membrane in methanol before soaking in transfer buffer.
**Prepare 6 filter papers for one gel/membrane sandwich.
3. Assemble transfer sandwich by orientating cathode, sponge, filter papers, gel, membrane, filter papers, sponge, and anode. The protein goes to the direction of cathode to anode.
4. Carefully move roller over the gel/membrane to remove air bubbles and excess buffer until complete contact is established.
5. Insert transfer cassette into transfer module. Notice that black side of cassette should be next to black side of module.
6. Fill transfer tank with pre-cooled transfer buffer to the highest water level.
7. Set constant voltage at 100 V. Transfer for 90 minutes at low temperature condition. Pre-stained protein marker should be visible on the membrane after transfer is completed.
Transfer of proteins to the membrane can be checked using Ponceau S staining before blocking step.
Supplemental Information for Using Q-PAGE™ Precast Gel
Adapting Q-PAGE™ Midi Precast Gels to Invitrogen Mini Gel Tank Electrophoresis System
1. Place the Q-PAGE Midi Precast Gels with notched plate facing toward yourself. No extra adapter is needed.
2. Seat the gels on the bottom of Mini Gel Tank and close the cassette clamp.
3. Fill chambers with running buffer to the level of the fill line. Ensure gel wells are completely covered.
Adapting Q-PAGE™ Midi Precast Gels to other electrophoresis system, please follow the manufacturer’s instruction.
Buffer recipes
2X sample buffer with reducing agent
62.5 mM Tris-HCl pH 6.8, 2% SDS, 25% (v/v) glycerol, 0.01% bromophenol blue, 5% β-mercaptoethanol or 100 mM DTT (added fresh)
10X Tris-Glycine running buffer
30.0 g Tris base, 144.0 g Glycine, 10.0 g SDS. Bring up the volume to 1 L with ddH2O.
1X running buffer
Dilute 100 ml 10X running buffer with 900 ml ddH2O.
10X transfer buffer
30.0 g Tris base, 144.0 g Glycine. Bring up the volume to 1 L with ddH2O.
1X transfer buffer
*Cool 1X transfer buffer to 4°C before using.
Dilute 100 ml 10X transfer buffer with 200 ml methanol and 700 ml ddH2O.
**Add SDS to 0.1% to promote transfer of high molecular weight proteins.
Troubleshooting Guidelines | ||
Problem | Possible Cause | Suggested Solution |
Well deformation | Pull one side of comb out of cassette. | Smoothly pull the comb straight out of the cassette. |
Bubbles between gel and cassette | Gel has been frozen or stored at wrong temperature. | Store Q-PAGE Precast Gels at 4°C. |
Buffer leaking from the inner chamber | Untight assembly of gels to the electrode modules | Reassemble Q-PAGE gels into the electrode modules. Fill outer chamber with 1X running buffer to the highest level. |
Samples do not sink into the wells. | Residual gel storage buffer in the wells | Rinse the gel wells with ddH2O or 1X running buffer before loading. |
Insufficient sample buffer | Use more sample buffer to prepare samples. | |
Current is zero and sample do not migrate into gel | Tape at bottom of gel not removed | Remove tape |
Gels run faster or more slowly than expected. | Incorrect running buffer | Check buffer composition. Use fresh 1X running buffer for inner chamber. |
Crooked bands at middle or bottom of gel | Gel has been frozen or stored at wrong temperature. | Store Q-PAGE Precast Gels at 4°C. |
Incorrect running buffer | Check buffer composition. Use fresh 1X running buffer for inner chamber. | |
Band pattern curves toward one or both sides of gel. | Buffer leaking from the inner chamber | Check assembly of gels into the electrode modules. |
Excessive heating of gel | Check buffer composition. Or dilute running buffer to 0.5-0.75X. Do not exceed recommended running conditions. | |
Insufficient buffer in inner or outer buffer chamber | Fill inner and outer chambers to completely cover gel wells. | |
Poor resolution or fuzzy bands | Excessive heating of gel | Check buffer composition. Do not exceed recommended running conditions. |
Incorrect running buffer | Check buffer composition. | |
Bands are missing on the membrane after Western transferring. | Proteins move in the wrong direction | Check the order of gel/membrane sandwich assembly, the direction of transfer cassette in transfer modules, and the polarity of connections to power supply. |
Swirls or missing bands; bands trail off in multiple directions on the membrane after Western transferring. | Contact between the membrane and the gel was poor; Air bubbles or excess buffer remains between the blotting membrane and the gel. | Use thicker/more filter paper in the gel/membrane sandwich Remove air bubbles and excess buffer between gel and membrane by carefully moving the roller over the membrane. |
Apparent molecular sizes of prestained protein markers are different as indicated. | Prestained protein markers used have not been calibrated for use with Q-PAGE gels. Dyes for staining protein markers affect the migration patterns of prestained proteins in different buffer systems. | Calibrate prestained protein markers against unstained proteins of known size or use SMOBIO’s ExcelBand™ Protein Markers. |
Gel Type | Bis-Tris | TGN (Tris-Glycine-Novel) | ||||||
Buffer systems | MOPS and MES | Tris-Glycine (Laemmli) | ||||||
Features | Clear and sharp bands, high resolution | Quick running, clear bands | ||||||
Cassette size | Mini Gel(10 x 8.3 cm) | Midi Gel(10 X 10 cm) | Mini Gel(10 x 8.3 cm) | Midi Gel(10 X 10 cm) | ||||
Electrophoresis system | Bio-Rad systems | Mini Gel Tank Xcell SureLock, Hoefer SE260 | Bio-Rad systems | Mini Gel Tank Xcell SureLock, Hoefer SE260 | ||||
Well format & Capacity | 12 wells, 25 μl/well | 15 wells, 22 μl/well | 12 wells, 40 μl/well | 15 wells, 28 μl/well | 12 wells, 25 μl/well | 15 wells, 22 μl/well | 12 wells, 40 μl/well | 15 wells,28 μl/well |
Gel percentage/ Cat. No. | 8% | 8% | 8% | 8% | 10% | 10% | 10% | 10% |
QP2110 | QP2120 | QP3110 | QP3120 | QP4210 | QP4220 | QP5210 | QP5220 | |
12% | 12% | 12% | 12% | 4-15% | 4-15% | 4-15% | 4-15% | |
QP2310 | QP2320 | QP3310 | QP3320 | QP4510 | QP4520 | QP5510 | QP5520 | |
4-12% | 4-12% | 4-12% | 4-12% |
|
|
|
| |
QP2510 | QP2520 | QP3510 | QP3520 |
|
|
|
|
Ready-to-use— premixed with a loading buffer for direct loading, no need to boil
Broad range— 310 kDa to 5 kDa
Pre-stained bands — for monitoring protein separation during electrophoresis and Western blotting transferring efficiency on membrane
Enhanced bands— for quick reference
Ready-to-use — no need of mixing or heating before sample loading
Direct visualization — 10 IgG-binding proteins for direct visualization on Western blots
Pre-stained bands — 4 pre-stained proteins for monitoring protein separation during electrophoresis and Western blotting transferring efficiency on membrane
Wide range — 10 clear bands from 15 to 200 kDa for size estimation
Quick reference — two enhanced bands (30 and 80 kDa)
Compatible to MASS analysis — compatible to the analysis of mass spectra, such as LC-MS/MS, MALDI-TOF, and etc.
High sensitivity — detection level achieve ~3 ng, similar to silver staining
Substitution of the Coomassie Blue protein staining method
SMOBIO
SMOBIO成立于2004年,公司在开发和制造分子生物学试剂和测试工具方面表现优异。其分子生物学试剂是市场上最受欢迎的一部分。提供的蛋白质标记物包含具有广谱预染蛋白的即用型稳定混合物,范围从50bp到25kb。此外,SMOBIO提供各种DNA聚合酶和逆转录酶,可以针对不同的实验室应用进行优化。专注领域:蛋白质标记、DNA梯度、PCR相关产品、克隆载体、荧光加载和染色染料、RT-PCR相关产品、Taq DNA聚合酶、Western Marker、dNTP等。
2004年,SMOBIO Technology,Inc.迅速出现在生物技术行业。SMOBIO Technology,Inc.首先采用独特的发酵技术,旨在生产高质量的功能性食品成分。建立成功的分销网络后,我们将继续专注于高质量产品,并开发了最先进的生物分子测试工具。我们的工具旨在通过提供高质量的DNA阶梯和蛋白质标记物来促进分子生物学和蛋白质科学研究。这些创新产品已受到业界和学术界人士的高度评价。自2008年以来,SMOBIO Technology,Inc.已展示出非常可观的市场份额。客户满意的证据表明,SMOBIO Technology,Inc.竭尽全力生产高质量的产品。
产品列表:
斯莫比 | TP1000 | ExcelTaq DNA聚合酶,5 U /μl,500 U x 1 | 500 U x 1 |
斯莫比 | TK1000 | ExcelTaq Klen-Taq DNA聚合酶,5 U /μl,500 U x 1 | 500 U x 1 |
斯莫比 | TF1000 | ExcelTaq SMO-HiFi DNA聚合酶,5 U /μl,500 U x 1 | 500 U x 1 |
斯莫比 | TP1100 | ExcelTaq 5X PCR预混液,200 Rxn | 200 Rxn |
斯莫比 | TP1200 | ExcelTaq 5X PCR主染料混合物,200 Rxn | 200 Rxn |
斯莫比 | TP1260 | ExcelTaq 5X荧光PCR预混液,200 Rxn | 200 Rxn |
斯莫比 | TP2000 | ExcelTaq血液直接DNA聚合酶,5 U /μl,500 U x 1 | 500 U x 1 |
斯莫比 | TP2100 | ExcelTaq 5X Blood Direct PCR Master Mix Kit,200 Rxn | 200 Rxn |
斯莫比 | TQ1100 | ExcelTaq Q-PCR预混液,200 Rxn | 200 Rxn |
斯莫比 | CV1000 | GetCloneTMPCR克隆载体,20 Rxn | 200 Rxn |
斯莫比 | RP1000 | ExcelRT反转录酶,20,000单位,100μl100 Rxn | 100微升100 Rxn |
斯莫比 | RP1100 | ExcelRT一步式RT-PCR试剂盒,50 Rxn | 50 Rxn |
Protein 相关产品 | |||
斯莫比 | PM1500 | ExcelBand全蓝色常规范围蛋白质标记物,250μlx 2 | 250微升×2 |
斯莫比 | PM1600 | ExcelBand全蓝色常规范围加蛋白质标记物,250μlx 2 | 250微升×2 |
斯莫比 | PM1700 | ExcelBand全蓝色广谱蛋白质标记物,250μlx 2 | 250微升×2 |
斯莫比 | PM2400 | ExcelBand粉色蓝色蛋白质标记物,250μlx 2 | 250微升×2 |
斯莫比 | PM2500 | ExcelBand 3色常规蛋白质标记物,250μlx 2 | 250微升×2 |
斯莫比 | PM2600 | ExcelBand 3色高范围蛋白质标记物,250μlx 2 | 250微升×2 |
斯莫比 | PM2700 | ExcelBand 3色广谱蛋白质标记物,250μlx 2 | 250微升×2 |
斯莫比 | PM5000 | ExcelBand 3色预染蛋白梯标准范围,250μlx 2 | 250微升×2 |
斯莫比 | PM5100 | ExcelBand 3色预染蛋白梯子高量程,250μlx 2 | 250微升×2 |
斯莫比 | PM5200 | ExcelBand 3色预染蛋白梯子,宽范围,250μlx 2 | 250微升×2 |
斯莫比 | PS1000 | FluoroStain蛋白荧光染色染料(红色,1000X),1毫升 | 1毫升 |
斯莫比 | PS1001 | FluoroStain蛋白荧光染色染料(红色,1000X),1 ml x 5 | 1毫升x 5 |
斯莫比 | PS2000 | FluoroStain蛋白荧光染色染料(金,100X),10毫升 | 10毫升 |
DNA 相关产品 | |||
斯莫比 | DM1100 | ExcelBand 50 bp DNA梯子,500μl | 500微升 |
斯莫比 | DM2100 | ExcelBand 100 bp DNA梯子,500μl | 500微升 |
斯莫比 | DM2300 | ExcelBand 100 bp + 3K DNA梯子,500μl | 500微升 |
斯莫比 | DM3100 | ExcelBand 1KB(0.25-10 kb)DNA梯子,500μl | 500微升 |
斯莫比 | DM3200 | ExcelBand 1KB Plus(0.1-10 kb)DNA梯子,500μl | 500微升 |
斯莫比 | DM4100 | ExcelBand XL 25 kb DNA梯子,宽量程(最高25 kb),500μl | 500微升 |
斯莫比 | DM1160 | FluoroBand 50 bp荧光DNA梯子,500μl | 500微升 |
斯莫比 | DM2160 | FluoroBand 100 bp荧光DNA梯子,500μl | 500微升 |
斯莫比 | DM2360 | FluoroBand 100 bp + 3K荧光DNA梯子,500μl | 500微升 |
斯莫比 | DM3160 | FluoroBand 1KB(0.25-10 kb)荧光DNA梯子,500μl | 500微升 |
斯莫比 | DM3260 | FluoroBand 1KB Plus(0.1-10 kb)荧光DNA梯子,500μl | 500微升 |
斯莫比 | DM4160 | FluoroBand XL 25 kb荧光DNA梯子,宽量程(最大25 kb),500μl | 500微升 |
斯莫比 | DL1000 | ExcelDye 6X DNA加载染料,橙色,5毫升x 2 | 5毫升x 2 |
斯莫比 | DL2000 | ExcelDye 6X DNA加载染料,绿色,5毫升x 2 | 5毫升x 2 |
斯莫比 | DL3000 | ExcelDye 6X DNA加载染料,蓝色,5毫升x 2 | 5毫升x 2 |
斯莫比 | DL4000 | ExcelDye 6X DNA加载染料,三色,5 ml x 2 | 5毫升x 2 |
斯莫比 | DL5000 | FluoroDye DNA荧光加载染料(绿色,6X),1毫升 | 1毫升 |
斯莫比 | DL5001 | FluoroDye DNA荧光加载染料(绿色,6X),1 ml x 5 | 1毫升x 5 |
斯莫比 | DS1000 | FluoroStain DNA荧光染色染料(绿色,10,000X),500μl | 500微升 |
斯莫比 | DS1001 | FluoroStain DNA荧光染色染料(绿色,10,000X),500μlx 5 | 500微升x 5 |
LED Light Box 切胶仪 | |||
斯莫比 | VE0100 | B-BOXTM蓝光LED落射照明器,DC 12伏,0.72安培 | 1套 |
斯莫比 | VE0101 | 适配器,AC 100-240V,50/60 Hz,1.8 m电源线,1 /包 | |
斯莫比 | VE0102 | 用于B-BOXTM的多角度滤板,1 /包 | |
斯莫比 | VE0103 | 用于B-BOXTM的琥珀色护目镜,1 /包 |